Arama Sonuçları..

Toplam 30 kayıt bulundu.
BT3™ Beta Titanium - Europa™ Form II - Platinum Proportion®

BT3™ Beta Titanium - Europa™ Form II - Platinum Proportion®

Europa™ Form II @ 92% & 84% Damon* CompatibleThese archforms are designed for treatment of patients with smaller tooth anatomy and/or spacing. After measuring all anterior teeth for over five years, Dr. Robert L. Waugh has crystalized a method to consistently deliver a predictable anterior display while idealizing functional coupling of anterior teeth.The Platinum Proportion® Archwire System takes the guess work out of archwire selection based on a simple system of measuring tooth width of the anteriors - cuspid to cuspid. This technique definitively provides the clinician the proper archwire based on the consolidated width.Pack of 25Pack of 10 (Solo-Pack™ option)*G&H is in no way affiliated with or endorsed by Ormco Corp. or Dr. Dwight DamonPlatinum Proportion is a registered service mark owned by Dr. Robert L. Waugh

http://www.eksenmedikal.com.tr/bt3-beta-titanium-europa-form-ii-platinum-proportion

Stainless Steel - Europa™ Form II - Platinum Proportion®

Stainless Steel - Europa™ Form II - Platinum Proportion®

Europa™ Form II @ 92% & 84% Damon* CompatibleThese archforms are designed for treatment of patients with smaller tooth anatomy and/or spacing. After measuring all anterior teeth for over five years, Dr. Robert L. Waugh has crystalized a method to consistently deliver a predictable anterior display while idealizing functional coupling of anterior teeth.The Platinum Proportion® Archwire System takes the guess work out of archwire selection based on a simple system of measuring tooth width of the anteriors - cuspid to cuspid. This technique definitively provides the clinician the proper archwire based on the consolidated width.Pack of 25Pack of 10 (Solo-Pack™ option)*G&H is in no way affiliated with or endorsed by Ormco Corp. or Dr. Dwight DamonPlatinum Proportion is a registered service mark owned by Dr. Robert L. Waugh

http://www.eksenmedikal.com.tr/stainless-steel-europa-form-ii-platinum-proportion

Stainless Steel - Keyhole 2 Loop - Trueform™ I

Stainless Steel - Keyhole 2 Loop - Trueform™ I

Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleLooped archwires offer excellent versatility for a variety of applications including anterior intrusion, space closure, elastic engagement, anterior retraction, etc.Looped archwires are offered in a range of sizes to accommodate most patients upper and lower arches, locating the loops between the lateral and cuspid. Manipulate anterior and posterior segments by activating the loops independently or in unison.To select proper size looped arch, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler. Looped Archwire Kit of 100 wires size distribution MM Sizing 22 24 26 28 30 32 34 36 38 40 42 44 Quantity 5 5 10 10 10 5 10 10 10 10 10 5 Pack of 10*MBT is a trademark of 3M Unitek **Tru-Arch is a trademark of Ormco

http://www.eksenmedikal.com.tr/stainless-steel-keyhole-2-loop-trueform-i

XR1™ Heat-Treated Stainless - Europa™ Form II - Platinum Proportion®

XR1™ Heat-Treated Stainless - Europa™ Form II - Platinum Proportion®

Europa™ Form II @ 92% & 84% Damon* CompatibleThese archforms are designed for treatment of patients with smaller tooth anatomy and/or spacing. After measuring all anterior teeth for over five years, we have crystalized a method to consistently deliver a predictable anterior display while idealizing functional coupling of anterior teeth.The Platinum Proportion® Archwire System takes the guess work out of archwire selection based on a simple system of measuring tooth width of the anteriors - cuspid to cuspid. This technique definitively provides the clinician the proper archwire based on the consolidated width.

http://www.eksenmedikal.com.tr/xr1-heat-treated-stainless-europa-form-ii-platinum-proportion

M5™ Copper Niti - Europa™ Form II - Platinum Proportion®

M5™ Copper Niti - Europa™ Form II - Platinum Proportion®

Europa™ Form II @ 92% & 84% Damon* CompatibleThese archforms are designed for treatment of patients with smaller tooth anatomy and/or spacing. After measuring all anterior teeth for over five years, Dr. Robert L. Waugh has crystallized a method to consistently deliver a predictable anterior display while idealizing functional coupling of anterior teeth.The Platinum Proportion® Archwire System takes the guess work out of archwire selection based on a simple system of measuring tooth width of the anteriors - cuspid to cuspid. This technique definitively provides the clinician the proper archwire based on the consolidated width.

http://www.eksenmedikal.com.tr/m5-copper-niti-europa-form-ii-platinum-proportion

G4™ Nickel Titanium - Europa™ Form II - Platinum Proportion®

G4™ Nickel Titanium - Europa™ Form II - Platinum Proportion®

Europa™ Form II @ 92% & 84% Damon* CompatibleThese archforms are designed for treatment of patients with smaller tooth anatomy and/or spacing. After measuring all anterior teeth for over five years, Dr. Robert L. Waugh has crystalized a method to consistently deliver a predictable anterior display while idealizing functional coupling of anterior teeth.The Platinum Proportion® Archwire System takes the guess work out of archwire selection based on a simple system of measuring tooth width of the anteriors - cuspid to cuspid. This technique definitively provides the clinician the proper archwire based on the consolidated width.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-europa-form-ii-platinum-proportion

V-CUT PHOTOGRAPHY RETRACTOR HI-HEAT 2PK

V-CUT PHOTOGRAPHY RETRACTOR HI-HEAT 2PK

Take intra-oral photos without and assistant. Patient can hold retractors. Elongated ends allow unrestricted access to anterior and posterior regions in the mouth. One side is for adults and the other is for children. Package of 2.

http://www.eksenmedikal.com.tr/liquid-etchant-for-tooth-preparation-1-9g-bottle

SWIVEL HEAD BRACKET POSITIONER

SWIVEL HEAD BRACKET POSITIONER

This stainless steel positioning device features four bracket height measurements: 3.5, 4.0, 4.5, and 5.0. Adjustable for use on both anterior and posterior teeth.Hinged tip adjustable to 45°. Works with .022 and .018 bracket systems.Autoclavable up to 370°F/188°C

http://www.eksenmedikal.com.tr/swivel-head-bracket-positioner

BT3™ Beta Titanium - Trueform™ I - Platinum Proportion®

BT3™ Beta Titanium - Trueform™ I - Platinum Proportion®

Trueform™ I @ 92% & 84% Roth / MBT* Square / Tru-Arch** CompatibleThese archforms are designed for treatment of patients with smaller tooth anatomy and/or spacing. After measuring all anterior teeth for over five years, Dr. Robert L. Waugh has crystalized a method to consistently deliver a predictable anterior display while idealizing functional coupling of anterior teeth.The Platinum Proportion® Archwire System takes the guess work out of archwire selection based on a simple system of measuring tooth width of the anteriors - cuspid to cuspid. This technique definitively provides the clinician the proper archwire based on the consolidated width.Pack of 25Pack of 10 (Solo-Pack™ option)*MBT is a trademark of 3M Unitek **Tru-Arch is a trademark of OrmcoPlatinum Proportion is a registered service mark owned by Dr. Robert L. Waugh

http://www.eksenmedikal.com.tr/bt3-beta-titanium-trueform-i-platinum-proportion

Stainless Steel - Trueform™ I - Platinum Proportion®

Stainless Steel - Trueform™ I - Platinum Proportion®

Trueform™ I @ 92% & 84% Roth / MBT* Square / Tru-Arch** CompatibleThese archforms are designed for treatment of patients with smaller tooth anatomy and/or spacing. After measuring all anterior teeth for over five years, Dr. Robert L. Waugh has crystalized a method to consistently deliver a predictable anterior display while idealizing functional coupling of anterior teeth.The Platinum Proportion® Archwire System takes the guess work out of archwire selection based on a simple system of measuring tooth width of the anteriors - cuspid to cuspid. This technique definitively provides the clinician the proper archwire based on the consolidated width.Pack of 25Pack of 10 (Solo-Pack™ option)*MBT is a trademark of 3M Unitek **Tru-Arch is a trademark of OrmcoPlatinum Proportion is a registered service mark owned by Dr. Robert L. Waugh

http://www.eksenmedikal.com.tr/stainless-steel-trueform-i-platinum-proportion

Stainless Steel - Keyhole 4 Loop - Trueform™ I

Stainless Steel - Keyhole 4 Loop - Trueform™ I

Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleLooped archwires offer excellent versatility for a variety of applications including anterior intrusion, space closure, elastic engagement, anterior retraction, etc.Looped archwires are offered in a range of sizes to accommodate most patients upper and lower arches, locating the loops between the lateral and cuspid. Manipulate anterior and posterior segments by activating the loops independently or in unison.To select proper size looped arch, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler. Looped Archwire Kit of 100 wires size distribution MM Sizing 22 24 26 28 30 32 34 36 38 40 42 44 Quantity 5 5 10 10 10 5 10 10 10 10 10 5 Pack of 10*MBT is a trademark of 3M Unitek **Tru-Arch is a trademark of Ormco

http://www.eksenmedikal.com.tr/stainless-steel-keyhole-4-loop-trueform-i

XR1™ Heat-Treated Stainless - Trueform™ I - Platinum Proportion®

XR1™ Heat-Treated Stainless - Trueform™ I - Platinum Proportion®

Trueform™ I @ 92% & 84% Roth / MBT* Square / Tru-Arch** CompatibleThese archforms are designed for treatment of patients with smaller tooth anatomy and/or spacing. After measuring all anterior teeth for over five years, we have crystalized a method to consistently deliver a predictable anterior display while idealizing functional coupling of anterior teeth.The Platinum Proportion® Archwire System takes the guess work out of archwire selection based on a simple system of measuring tooth width of the anteriors - cuspid to cuspid. This technique definitively provides the clinician the proper archwire based on the consolidated width.

http://www.eksenmedikal.com.tr/xr1-heat-treated-stainless-trueform-i-platinum-proportion

G4™ Nickel Titanium - Trueform™ I - Platinum Proportion®

G4™ Nickel Titanium - Trueform™ I - Platinum Proportion®

  Trueform™ I @ 92% & 84% Roth / MBT* Square / Tru-Arch** CompatibleThese archforms are designed for treatment of patients with smaller tooth anatomy and/or spacing. After measuring all anterior teeth for over five years, Dr. Robert L. Waugh has crystalized a method to consistently deliver a predictable anterior display while idealizing functional coupling of anterior teeth.The Platinum Proportion® Archwire System takes the guess work out of archwire selection based on a simple system of measuring tooth width of the anteriors - cuspid to cuspid. This technique definitively provides the clinician the proper archwire based on the consolidated width.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-trueform-i-platinum-proportion

G4™ Nickel Titanium - Trueform™ I - Platinum Proportion®

G4™ Nickel Titanium - Trueform™ I - Platinum Proportion®

  Trueform™ I @ 92% & 84% Roth / MBT* Square / Tru-Arch** CompatibleThese archforms are designed for treatment of patients with smaller tooth anatomy and/or spacing. After measuring all anterior teeth for over five years, Dr. Robert L. Waugh has crystalized a method to consistently deliver a predictable anterior display while idealizing functional coupling of anterior teeth.The Platinum Proportion® Archwire System takes the guess work out of archwire selection based on a simple system of measuring tooth width of the anteriors - cuspid to cuspid. This technique definitively provides the clinician the proper archwire based on the consolidated width.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-trueform-i-platinum-proportion-1

Stainless Steel - T-Loop - Trueform™ I

Stainless Steel - T-Loop - Trueform™ I

Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleLooped archwires offer excellent versatility for a variety of applications including anterior intrusion, space closure, elastic engagement, anterior retraction, etc.Looped archwires are offered in a range of sizes to accommodate most patients upper and lower arches, locating the loops between the lateral and cuspid. Manipulate anterior and posterior segments by activating the loops independently or in unison.To select proper size looped arch, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler. Looped Archwire Kit of 100 wires size distribution MM Sizing 24 26 28 30 32 34 36 38 40 42 44 46 Quantity 5 10 10 10 5 5 10 10 10 10 10 5 Pack of 10*MBT is a trademark of 3M Unitek **Tru-Arch is a trademark of Ormco

http://www.eksenmedikal.com.tr/stainless-steel-t-loop-trueform-i

BioForce

BioForce

BioForce - Square or Rectangluar   Optimally biological forces begin at approximately 80 grams of force at the anteriors, and gradually increase to approximately 300 grams of force in the molars. Also available with IONGUARD. Optimal Tooth Movement and Ideal Biological Forces As this chart shows, the optimal force needed to move anteriors is not the same as the optimal force needed to move molars. If a force is designed to move anteriors, it is too light to move molars. If a force is great enough to move molars, the force is too strong - traumatically strong - for anteriors. Other wires offer one force at a time, requiring at least two or three wire changes to achieve the desired movement. BioForce exhibits low forces at the anterior, gradually increases force in the bicuspids, and again in the molars. Each tooth receives the optimal biological force necessary to move specific teeth in one wire. Anterior Region of arch form has the lowest heat-activated force, as anterior teeth have the lightest roots. The Bicuspid Region of the arch maintains a slightly greater heat-activated force to move larger rooted bicuspids. The Posterior Region of the arch form has the greatest heat-activated force within the archwire for moving thestrong-rooted molars. BioForce also shares the properties of all Sentalloy wires and is designed to deliver a gentle, light continuous force to mitigate periodontal stress. UNIQUE PROPERTIES OF SENTALLOY SUPERELASTIC WIRES Body Heat Activation At room temperature, Sentalloy wires are soft, pliable, and easy to engage. Once warmed to body temperature the wire gently and predictably guides the teeth to the present arch form. Superelasticity Even when severely malposed, Sentalloy continues to exert its gentle, near constant forces as the tooth moves. Shape Memory Effect Sentalloy will take displacements up to 90 degrees without deforming. Its overwhelming desire to return to its original shape actually promotes tooth movement with fewer 0wire changes and fewer patient visits. IONGUARD - IONGUARD is not a coating; it is a fundamental change in the wire’s surface. Without changing the wire’s dimensions, or altering any of the wire’s unique superelastic properties, the process produces sliding mechanics comparable to stainless steel, while sealing the occlusal surface to reduce nickel leaching and breakage.

http://www.eksenmedikal.com.tr/bioforce-square-or-rectangluar

G4™ Nickel Titanium - Bioform III - G4orce™

G4™ Nickel Titanium - Bioform III - G4orce™

Bioform III MBT* Tapered / Ideal** CompatibleG4orce™ is a G4™ Nickel Titanium wire with 3 distinct zones offering progressive forces that increase from anterior to posterior. Light anterior force (100g), medium cuspid/bicuspid force (200g), and a heavy molar force (300g) when applied to a 19x25 wire.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-bioform-iii-g4orce

Accu-Force™ and Accu-Force™ G3 - An Economic NiTi Wire Option

Accu-Force™ and Accu-Force™ G3 - An Economic NiTi Wire Option

  These advanced superelastic and heat-activated archwires are available in round, square, and rectangular for all stages of treatment. Superelastic provides gentle, nearly constant forces. Shape memory effect provides an overwhelming desire to return to original shape. Heat activated are soft and pliable, easy to engage at room temperature, may be chilled for easier ligation. Optimal tooth movement and ideal biological forces in Accu-Force™ G3 wires. Accu-Force™ round is used as an initial archwire. The superelastic  NiTi wire provides near constant  forces during the leveling and  aligning stage of treatment. Accu-Force™ G3 - Sqaure or Rectangular is an advanced superelastic archwire for early to mid treatment. Accu-Force™ G3 starts with low, gentle forces for the anteriors, and increases force in the posterior, where it plateaus in the molar region, all in the same wire.

http://www.eksenmedikal.com.tr/accu-force-and-accu-force-g3-an-economic-niti-wire-option

Intranol CTA

Intranol CTA

The NiTi memory and force properties of Intranol CTA are excellent for incisor flaring, leveling anterior occlusal cants, molar tip back, correction of minor open bites, Class II molar correction, and finishing.

http://www.eksenmedikal.com.tr/intranol-cta

M5™ Copper Nickel Titanium - Preformed Lingual

M5™ Copper Nickel Titanium - Preformed Lingual

Preformed Lingual These archforms were developed to meet the challenging mechanics of modern lingual treatment - designed and adapted precisely to lingual anatomy. Three anterior sizes in both upper and lower ensure a proper fit.A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-preformed-lingual

G4™ Nickel Titanium - Pre Torqued - Europa™ Form II

G4™ Nickel Titanium - Pre Torqued - Europa™ Form II

Europa™ Form II Damon* CompatibleEffective on both upper and lower arches, our 20° pre-torqued nickel titanium wires provide early and continuous translation of torque forces to anteriors that can be applied labially or lingually, simply by reversing the orientation of the wire.Available in 3 mm span sizes. Typically, a 28mm span is applied to the lower arch, 34mm & 38mm for the upper. To select proper mm span, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-pre-torqued-europa-form-ii

G4™ Nickel Titanium - Pre Torqued - RC - Europa™ Form II

G4™ Nickel Titanium - Pre Torqued - RC - Europa™ Form II

Europa™ Form II Reverse Curve Damon* CompatibleEffective on both upper and lower arches, our 20° pre-torqued nickel titanium wires provide early and continuous translation of torque forces to anteriors that can be applied labially or lingually, simply by reversing the orientation of the wire.Available in 3 mm span sizes. Typically, a 28mm span is applied to the lower arch, 34mm & 38mm for the upper. To select proper mm span, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-pre-torqued-rc-europa-form-ii

G4™ Nickel Titanium - Preformed Lingual

G4™ Nickel Titanium - Preformed Lingual

Preformed Lingual These archforms were developed to meet the challenging mechanics of modern lingual treatment - designed and adapted precisely to lingual anatomy. Three anterior sizes in both upper and lower ensure a proper fit.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-preformed-lingual

BITE BUMPER™

BITE BUMPER™

Bite Bumpers™ work to open deep bite cases by allowing the anteriors to ride up and out of occlusion. The Bite Bumpers™ eliminate bond failures of brackets and are especially valuable with ceramic or self-ligating brackets.The unique fixed "placement-jig" guarantees the correct height on the lingual of the tooth an makes sure the two Bite Bumpers™ are 100% parallel.The Bite Bumpers™ are made of a composite polymer that is more comfortable, aesthetic and will increase biocompatibility in nickel sensitive patients.Bite-Bumpers™ are bonded in the same manner as plastic or composite brackets with a slotted mechanical bonding base.Bite Bumper is a registered trademark by Gestenco International AB, Sweden

http://www.eksenmedikal.com.tr/bite-bumper

G4™ Nickel Titanium - Pre Torqued - Reverse Curve I

G4™ Nickel Titanium - Pre Torqued - Reverse Curve I

Reverse Curve I Original with moderate curve, torque and distal toe-in.Effective on both upper and lower arches, our 20° pre-torqued nickel titanium wires provide early and continuous translation of torque forces to anteriors that can be applied labially or lingually, simply by reversing the orientation of the wire.Available in 3 mm span sizes. Typically, a 28mm span is applied to the lower arch, 34mm & 38mm for the upper. To select proper mm span, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-pre-torqued-reverse-curve-i

G4™ Nickel Titanium - Pre Torqued - Trueform™ I

G4™ Nickel Titanium - Pre Torqued - Trueform™ I

Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleEffective on both upper and lower arches, our 20° pre-torqued nickel titanium wires provide early and continuous translation of torque forces to anteriors that can be applied labially or lingually, simply by reversing the orientation of the wire.Available in 3 mm span sizes. Typically, a 28mm span is applied to the lower arch, 34mm & 38mm for the upper. To select proper mm span, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-pre-torqued-trueform-i

G4™ Nickel Titanium - Trueform™ I - G4orce™

G4™ Nickel Titanium - Trueform™ I - G4orce™

Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleG4orce™ is a G4™ Nickel Titanium wire with 3 distinct zones offering progressive forces that increase from anterior to posterior. Light anterior force (100g), medium cuspid/bicuspid force (200g), and a heavy molar force (300g) when applied to a 19x25 wire.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-trueform-i-g4orce

BT3™ Beta Titanium - T Loop - Trueform™ I

BT3™ Beta Titanium - T Loop - Trueform™ I

Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleLooped archwires offer excellent versatility for a variety of applications including anterior intrusion, space closure, elastic engagement, anterior retraction, etc.Our Nickel-Free BT3™ Beta Titanium provides force levels that are 45% less than those of equivalent stainless steel arches and represents the latest material science available in Titanium Molybdenum archwires. T-Loop Archwire Kit of 50 wires size distribution MM Sizing 24 26 28 30 32 34 36 38 40 42 Quantity 5 5 5 5 5 5 5 5 5 5 Pack of 10*MBT is a trademark of 3M Unitek **Tru-Arch is a trademark of Ormco

http://www.eksenmedikal.com.tr/bt3-beta-titanium-t-loop-trueform-i

GAC Molar Distallization Coils

GAC Molar Distallization Coils

Maxillary molars can be moved distally in 4-7 months without patient cooperation using our 100 gram Stop Wound Open Coil Springs. A modified Nance or A.C.C.O. may be used as an anchorage device initially. The coils are placed between the 1st bicuspid and the 1st molar – by passing the 2nd bicuspid. The coils are then activated against the molar using an archwire lock or our special crimpable stop. Cut the Stop Wound Open Coils so that they extend to the end of the buccal tube. Ligate the archwire to the 1st bicuspid, set the stop, then slide the coil onto the archwire. Next, feed the archwire into the tube, ensuring that the archwire is fully inserted with 2mm of wire extending beyond the tube. Uprighting springs may be used from the 1st bicuspid to the distal of the laterals to control any anterior movement. Using this system, you will see 1mm per month in space gained, with any anchorage loss well within clinically acceptable limits.

http://www.eksenmedikal.com.tr/gac-molar-distallization-coils

GAC <b class=red>Anterior</b> Retracting Springs

GAC Anterior Retracting Springs

Anterior Retracting Springs are available for segmented retraction of the maxillary four incisors. The increased force in these springs was designed to overcome the resistance of the roots and the rectangular archwire. Stops may be set on the archwire to ensure the proper destination. The eyelets are engaged from our crimped hook or an archwire lock to the molar hook. Expect 1mm of movement per month of activation.

http://www.eksenmedikal.com.tr/gac-anterior-retracting-springs

 
3WTURK CMS v6.03WTURK CMS v6.0